Abstract
The present study aimed to compare muscle architecture and electromyographic activity during isotonic (IT) and isokinetic (IK) knee extensors eccentric contractions. Seventeen subjects were assigned in test and reproducibility groups. During test session, subjects performed two IT and two IK sets of eccentric contractions of knee extensor muscles. Torque, angular velocity, VL architecture and EMG activity of agonist (vastus lateralis, VL; vastus medialis; rectus femoris) and antagonist (semitendinosus; biceps femoris, BF) muscles were simultaneously recorded and averaged on a 5° window. Torque–angle and angular velocity–angle relationships exhibited differences in mechanical load between the IT and IK modes. Changes in muscle architecture were similar in both modes, since VL fascicles length increased and fascicle angle decreased, resulting in a decrease in muscle thickness during eccentric contraction. Agonist activity and BF co-activity levels were higher in IT mode than in IK mode at short muscle lengths, whereas agonist activity was higher in IK mode than in IT mode at long muscle lengths. Differences in mechanical load between both modes induced specific neuromuscular responses in terms of agonist activity and antagonist co-activity. These results suggest that specific neural adaptations may occur after IT or IK eccentric training. This hypothesis needs to be tested in order to gain new insights concerning the most effective eccentric protocols based on whether the objective is sportive or clinical.
Similar content being viewed by others
References
Aagaard P, Simonsen EB, Trolle M, Bangsbo J, Klausen K (1995) Isokinetic hamstring/quadriceps strength ratio: influence from joint angular velocity, gravity correction and contraction mode. Acta Physiol Scand 154:421–427
Abellaneda S, Guissard N, Duchateau J (2009) The relative lengthening of the myotendinous structures in the medial gastrocnemius during passive stretching differs among individuals. J Appl Physiol 106:169–177
Babault N, Pousson M, Michaut A, Van Hoecke J (2003) Effect of quadriceps femoris muscle length on neural activation during isometric and concentric contractions. J Appl Physiol 94:983–990
Bigland B, Lippold OC (1954) The relation between force, velocity and integrated electrical activity in human muscles. J Physiol 123:214–224
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310
Blazevich AJ, Gill ND, Zhou S (2006) Intra- and intermuscular variation in human quadriceps femoris architecture assessed in vivo. J Anat 209:289–310
Burden A, Bartlett R (1999) Normalisation of EMG amplitude: an evaluation and comparison of old and new methods. Med Eng Phys 21:247–257
Chino K, Mitsukawa N, Kobayashi K, Miyoshi Y, Oda T, Kanehisa H, Fukunaga T, Fukashiro S, Kawakami Y (2009) The influence of fascicle behavior on the lack of velocity dependence in eccentric joint torque in humans: in vivo observation. J Appl Biomech 25:111–118
Duchateau J, Enoka RM (2008) Neural control of shortening and lengthening contractions: influence of task constraints. J Physiol 586:5853–5864
Duclay J, Martin A (2005) Evoked H-reflex and V-wave responses during maximal isometric, concentric, and eccentric muscle contraction. J Neurophysiol 94:3555–3562
Duclay J, Martin A, Robbe A, Pousson M (2008) Spinal reflex plasticity during maximal dynamic contractions after eccentric training. Med Sci Sports Exerc 40:722–734
Enoka RM (1996) Eccentric contractions require unique activation strategies by the nervous system. J Appl Physiol 81:2339–2346
Fukunaga T, Ichinose Y, Ito M, Kawakami Y, Fukashiro S (1997) Determination of fascicle length and pennation in a contracting human muscle in vivo. J Appl Physiol 82:354–358
Fukunaga T, Kubo K, Kawakami Y, Fukashiro S, Kanehisa H, Maganaris CN (2001) In vivo behaviour of human muscle tendon during walking. Proc Biol Sci 268:229–233
Guilhem G, Cornu C, Guével A (2010a) Neuromuscular and muscle–tendon system adaptations to isotonic and isokinetic eccentric exercise. Ann Phys Rehabil Med 53:319–341
Guilhem G, Cornu C, Nordez A, Guevel A (2010b) A new device to study isoload eccentric exercise. J Strength Cond Res 24:3476–3483
Guilhem G, Guével A, Cornu C (2010c) A standardization method to compare isotonic vs. isokinetic eccentric exercises. J Electromyogr Kinesiol 20:1000–1006
Herbert RD, Gandevia SC (1995) Changes in pennation with joint angle and muscle torque: in vivo measurements in human brachialis muscle. J Physiol 484(Pt 2):523–532
Hermens HJ, Freriks B, Disselhorst-Klug C, Rau G (2000) Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol 10:361–374
Hopkins WG (2000) Measures of reliability in sports medicine and science. Sports Med 30:1–15
Housh DJ, Housh TJ, Weir JP, Weir LL, Evetovich TK, Donlin PE (1998) Effects of unilateral eccentric-only dynamic constant external resistance training on quadriceps femoris cross-sectional area. J Strength Cond Res 12:192–198
Ichinose Y, Kawakami Y, Ito M, Kanehisa H, Fukunaga T (2000) In vivo estimation of contraction velocity of human vastus lateralis muscle during “isokinetic” action. J Appl Physiol 88:851–856
Ishikawa M, Finni T, Komi PV (2003) Behaviour of vastus lateralis muscle-tendon during high intensity SSC exercises in vivo. Acta Physiol Scand 178:205–213
Junior VA, Bottaro M, Pereira MC, Andrade MM, Júnior PPR, Carmo JC (2010) Electromyographic analyses of muscle pre-activation induced by single joint exercise. Rev Bras Fisioter 14:158–165
Kellis E, Baltzopoulos V (1998) Muscle activation differences between eccentric and concentric isokinetic exercise. Med Sci Sports Exerc 30:1616–1623
Komi PV, Linnamo V, Silventoinen P, Sillanpaa M (2000) Force and EMG power spectrum during eccentric and concentric actions. Med Sci Sports Exerc 32:1757–1762
Kubo K, Kanehisa H, Azuma K, Ishizu M, Kuno SY, Okada M, Fukunaga T (2003) Muscle architectural characteristics in young and elderly men and women. Int J Sports Med 24:125–130
Maxwell LC, Faulkner JA, Hyatt GJ (1974) Estimation of number of fibers in guinea pig skeletal muscles. J Appl Physiol 37:259–264
Mullany H, O’Malley M, St Clair Gibson A, Vaughan C (2002) Agonist-antagonist common drive during fatiguing knee extension efforts using surface electromyography. J Electromyogr Kinesiol 12:375–384
Nakazawa K, Kawakami Y, Fukunaga T, Yano H, Miyashita M (1993) Differences in activation patterns in elbow flexor muscles during isometric, concentric and eccentric contractions. Eur J Appl Physiol Occup Physiol 66:214–220
Nardone A, Romano C, Schieppati M (1989) Selective recruitment of high-threshold human motor units during voluntary isotonic lengthening of active muscles. J Physiol 409:451–471
Nordez A, Casari P, Cornu C (2008) Effects of stretching velocity on passive resistance developed by the knee musculo-articular complex: contributions of frictional and viscoelastic behaviours. Eur J Appl Physiol 103:243–250
Pasquet B, Carpentier A, Duchateau J (2005) Change in muscle fascicle length influences the recruitment and discharge rate of motor units during isometric contractions. J Neurophysiol 94:3126–3133
Pasquet B, Carpentier A, Duchateau J (2006) Specific modulation of motor unit discharge for a similar change in fascicle length during shortening and lengthening contractions in humans. J Physiol 577:753–765
Pinniger GJ, Steele JR, Thorstensson A, Cresswell AG (2000) Tension regulation during lengthening and shortening actions of the human soleus muscle. Eur J Appl Physiol 81:375–383
Reeves ND, Narici MV (2003) Behavior of human muscle fascicles during shortening and lengthening contractions in vivo. J Appl Physiol 95:1090–1096
Remaud A, Cornu C, Guével A (2009) Agonist muscle activity and antagonist muscle co-activity levels during standardized isotonic and isokinetic knee extensions. J Electromyogr Kinesiol 19:449–458
Remaud A, Cornu C, Guével A (2010) Neuromuscular adaptations to 8-week strength training: isotonic versus isokinetic mode. Eur J Appl Physiol 108:59–69
Sleivert GG, Wenger HA (1994) Reliability of measuring isometric and isokinetic peak torque, rate of torque development, integrated electromyography, and tibial nerve conduction velocity. Arch Phys Med Rehabil 75:1315–1321
Visnes H, Bahr R (2007) The evolution of eccentric training as treatment for patellar tendinopathy (jumper’s knee): a critical review of exercise programmes. Br J Sports Med 41:217–223
Acknowledgments
This study was supported by grants from the «Région des Pays de la Loire» and the «Réseau Recherche et Sport en Pays de la Loire» (France).
Conflict of interest
Authors had no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Supplementary material:
Bland–Altman plots for the amount of work performed (a) and mean angular velocity (b) between isotonic (IT) and isokinetic (IK) eccentric exercises. WIT: amount of work performed in isotonic mode; WIK: amount of work performed in isokinetic mode; \( \bar{\omega }_{\text{IT}} \): mean angular velocity in isotonic mode; \( \bar{\omega }_{\text{IK}} \): mean angular velocity in IK mode; CI: confidence interval (TIFF 4523 kb)
Rights and permissions
About this article
Cite this article
Guilhem, G., Cornu, C. & Guével, A. Muscle architecture and EMG activity changes during isotonic and isokinetic eccentric exercises. Eur J Appl Physiol 111, 2723–2733 (2011). https://doi.org/10.1007/s00421-011-1894-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00421-011-1894-3