Highlights

  • Effects of organic contaminants in air on PEMFC were studied with a segmented cell.

  • Cathode exposure to 100 ppm C3H6 resulted in performance loss of 130 mV at 1.0 A cm−2

  • PEMFC poisoning by 20 ppm methyl methacrylate led to a voltage loss of 80 mV.

  • A moderate performance decline of 60 mV was caused by 5.3⋅103 ppm IPA in air.

  • Performance loss is due to the contaminants chemisorption and oxidation on Pt.

Abstract

This paper studies the effects of propylene, methyl methacrylate (MMA) and isopropanol (IPA) in air on the spatial performance of proton exchange membrane fuel cells (PEMFCs). The introduction of 100 ppm C3H6 into the oxidant stream resulted in a performance decrease of 130 mV at 1.0 A cm−2, whereas 20 ppm MMA caused a voltage loss of 80 mV. A moderate performance decline of 60 mV was detected in the presence of 5.3⋅103 ppm IPA in air. Spatial electrochemical impedance spectroscopy (EIS) data showed an increase in charge and mass transfer resistances under exposure to C3H6 and MMA, although IPA did not affect the impedance. The observed PEMFC performances, local current redistributions and EIS data can be explained by the adsorption of contaminants on the Pt surface, their subsequent transformations, and their impacts on the electrochemical surface area and oxygen reduction mechanism. It was assumed that the studied contaminants were oxidized mainly to CO2 via electrochemical and chemical pathways under the operating conditions and at the cathode potential. Self-recovery of PEMFC performance was observed for each contaminant after halting its introduction into the air. Possible contaminant oxidation/reduction mechanisms and their correlations with spatial performance and EIS are presented and discussed.

Introduction

Electrochemical energy conversion systems have attracted attention and been a focus of research for several decades, which has led to the commercialization of proton exchange membrane fuel cell (PEMFC) vehicles and residential power supply units. The first results of the early commercialization stage clearly indicated the need for further improvements in durability, reliability, environmental adaptability and cost reduction of fuel cell-powered systems. To produce electricity, the PEMFC requires hydrogen as a fuel and air as an oxidant. Air is an abundant and freely available reagent for fuel cell operations, but its availability varies in the presence of different air impurities, such as SO2, NO2, CO, O3, particulates and volatile organic compounds (VOCs). Inorganic (SO2, H2S, NH3, NO2) and organic (C6H6, 1,3-butadiene, toluene and warfare agents) air pollutants negatively affect PEMFC performance [[1], [2], [3], [4], [5], [6], [7], [8], [9], [10], [11], [12], [13], [14], [15]]. The performance decline is primarily due to chemisorption of contaminants on the catalyst (Pt) surface, followed by a decrease in the electrochemical surface area (ECSA) and a change in the oxygen reduction reaction (ORR) pathway from a 4-electron mechanism to a less efficient combination of 4- and 2-electron mechanisms [8,11,12,15]. Other contamination effects might include a decrease in ionomer proton conductivity and alterations in the hydrophilic/hydrophobic properties of membrane electrode assembly (MEA) components, which contribute to the observed PEMFC performance drop [12].

In a continuing effort to systematically evaluate PEMFC performance under exposure to VOCs, several air contaminants have been identified for detailed investigation [14]. Selected VOCs include C2H2 (alkynes), C6H6 and C10H8 (arenes), CH3CN (nitriles), CH3Br (alkyl halides), C3H6 (alkenes), i-C3H7OH (alcohols) and methyl methacrylate (CH2=C(CH3)COOCH3, esters). These chemical compounds are widely used in the chemical industry and in household chemical goods, and thus they might be present in ambient air. Our earlier publications offer incontestable evidence that all of these compounds cause serious damage to fuel cell performance [[13], [14], [16], [17], [18], [19], [20]]. The work is important for understanding the environmental adaptability and tolerance of PEMFCs to contaminants under field conditions, which is very valuable to fuel cell manufacturers because fuel cell vehicles are being commercially deployed (Toyota Mirai, Honda Clarity, Hyundai Tucson in the United States). Car manufacturers urgently need to obtain as much information as possible to minimize failure risks (warranty liabilities), diagnose and service vehicles affected by contamination and prevent failures.

The current work focuses on propylene, methyl methacrylate (MMA) and isopropanol (IPA) as potential air contaminants (Table 1). The annual production of propylene is approximately 100 million tons worldwide through petroleum refining, natural gas processing and ethylene production via steam/catalytic cracking of hydrocarbon feedstock. Additionally, C3H6 is a major chemical intermediate for manufacturing of polypropylene, acrylonitrile, propylene oxide, isopropanol and cumene. The propylene concentration measured in ambient air at rural and remote sites worldwide ranges from 0.01 to 7 ppb, and in urban and polluted air, its concentration varies from 0.3 to 32 ppb [[21], [22], [23]]. Suburban locations near industrial complexes or petrochemical plants might have C3H6 air concentrations of 100–260 ppb [22,24]. Propylene is expected to be released to the environment primarily from industrial manufacturing and use operations. Although C3H6 is not a gasoline component, it is present in motor vehicle exhaust as a result of fuel-rich combustion of hydrocarbon fuels. Thus, burning of hydrocarbon fuels, wood, cigarettes and synthetic polymers all release propylene to the atmosphere.

Methyl methacrylate is another airborne contaminant and was chosen in this study as a model ester to represent this class of organic compounds due to its wide application in production of polymethyl methacrylate (PMMA) plastics and co-polymer methyl methacrylate-butadiene-styrene. Acrylic sheets made by casting, molding or extruding of polymethyl methacrylate are used in safety glazing, panels and manufacturing products that require good optical clarity and stability, such as lighting. Methyl methacrylate polymers and copolymers are widely used in paint and surface coatings. Other applications of methacrylate polymers include dental prostheses, surgical bone cements and leaded acrylic radiation shields. The main source of MMA release to the atmosphere is the chemical industry, and its concentration in air ranges from undetected to 11.5 ppm during the manufacturing process. An exposure of 0.5–165 ppm was reported for polymethyl methacrylate production [[25], [26], [27]]. The average air MMA concentration estimated based on the fugacity model is ∼0.244 mg m−3 (∼0.06 ppm) [27,28], and thus its presence in regular indoor and outdoor environments is low.

The third potential contaminant is isopropanol, which is widely used as a solvent, heat-exchange media, intermediate in the chemical industry and defroster (for car windows). Isopropanol also has applications in the cosmetic and pharmaceutical industries. The IPA concentration in air varies in the range of 0.2–16 ppb [29,30], and the maximum indoor concentration was found to be 90 ppb [31]. It is expected that the isopropanol concentration near industrial sites could be significantly higher, and its permissible exposure limit is 400 ppm according to the US Occupational Safety Health Administration [32].

Experimental data on fuel cell performance under cathode exposure to these contaminants are quite limited, and the observations are not explained in full volume [13,14,16]. It was reported that 100 ppm of C3H6 caused a performance loss of 120–130 mV at 80 °C and a constant current hold of 1.0 A cm−2 for single-cell operation [13]. Additionally, the average cell voltage of a 36-cell stack operated at 55 °C decreased from 0.630 to 0.380 V under injection of 50 ppm C3H6 [16]. PEMFC cathode poisoning with 20 ppm of methyl methacrylate and isopropanol in the air stream led to performance losses of 450 and 10 mV, respectively, at 45 °C and 1.0 A cm−2 [14]. All of these results were obtained using unaltered single-cell designs, which do not reveal the localized PEMFC behavior over the MEA active area, whereas a segmented cell system ensures simultaneous spatial monitoring of voltage, current and impedance and demonstrates excellent results for studying the effects of operating conditions and fuel and air contaminants on fuel cell performance [[17], [18], [19], [20], [33], [34], [35], [36], [37], [38], [39], [40], [41], [42], [43], [44], [45]]. Application of the segmented cell system for studying localized PEMFC behavior in the presence of contamination has seldom been completed for MEAs with active areas and conditions of commercial relevance (>50 cm2). Our previous detailed studies of spatial PEMFC behavior under cathode poisoning by C2H2, CH3CN, arenes and CH3Br demonstrated a non-uniform performance distribution over the MEA active area, which could lead to inhomogeneous degradation and premature failure [[17], [18], [19], [20]]. Moreover, the chemical and electrochemical properties of air contaminants and their interactions with the catalyst strongly determine the localized fuel cell performance. This paper is a continuation of our publications (C2H2, CH3CN, C6H6, C10H8 and CH3Br [[17], [18], [19], [20]]) and presents the spatial fuel cell phenomena that occur during cathode poisoning by propylene, methyl methacrylate and isopropanol. The results offer insights for comprehension of fuel cell contamination and environmental tolerance as well as suggestions for PEMFC durability improvement. In this work the chosen concentrations of pollutants in the air stream are higher than those observed in typical environmental conditions to accelerate contamination effects on fuel cell performance.

Section snippets

Experimental

All experimental work was performed using a fuel cell test station modified in-house to the required specifications, a Solartron SI 1287/electrochemical interface and a segmented cell system developed at the Hawaii Natural Energy Institute and based on previous studies [[46], [47], [48], [49]]. The segmented cell system allows simultaneous measurements of spatial impedance spectroscopy (EIS), cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The segmented cell hardware was based on

PEMFC behavior under contaminant poisoning

Fig. 1 presents the PEMFC performance under exposure to C3H6, MMA and i-C3H7OH in terms of the segment voltages and normalized currents vs. experiment time. The normalized current is the ratio of the measured current to its initial value prior to injection of an impurity into the cathode gas stream. Contamination experiments were performed under control of the overall cell current density of 1.0 A cm−2 and consisted of three stages: 1) pre-poisoning conducted with pure air, 2) poisoning when an

Conclusion

Localized PEMFC performance under cathode poisoning by propylene, methyl methacrylate and isopropanol was studied via a segmented cell system and under galvanostatic control of the cell current. The introduction of 100 ppm C3H6 into the air stream caused a cell voltage decrease of 130 mV at 1.0 A cm−2. PEMFC operated with exposure to 20 ppm MMA showed a decrease in performance of 80 mV, whereas the presence of 5.3⋅103 ppm IPA in air led to a moderate decrease of 60 mV. In addition, the

Acknowledgements

The authors gratefully acknowledge the Department of Energy (award DE-EE0000467) and the Office of Naval Research (award N00014-12-1-0496) for funding of this work and the Hawaiian Electric Company for their ongoing support of the operation of the Hawaii Sustainable Energy Research Facility. The authors also thank Günter Randolf and Keith Bethune for valuable support regarding system operation and for data discussions.

References (90)

  • J.A. Giannovario et al.

    Analysis of trace pollutants in the air by means of cryogenic gas chromatography

    J. Chromatogr

    (1976)
  • E. Gallego et al.

    Determining indoor air quality and identifying the origin of odour episodes in indoor environment

    J. Environ. Sci.

    (2009)
  • L.C. Pérez et al.

    Segmented polymer electrolyte membrane fuel cells – a review

    Renew. Sustain. Energy Rev.

    (2011)
  • F.N. Büchi et al.

    Dependence of current distribution on water management in PEFC of technical size

    J. Power Sources

    (2005)
  • D.G. Sanchez et al.

    PEMFC operation failure under severe dehydration

    Int. J. Hydrogen Energy

    (2012)
  • T. Tingelöf et al.

    The influence of CO2, CO and air bleed on the current distribution of a polymer electrolyte fuel cell

    Int. J. Hydrogen Energy

    (2008)
  • M. Boaventura et al.

    The influence of CO on the current density distribution of high temperature polymer electrolyte membrane fuel cells

    Electrochim. Acta

    (2011)
  • T.V. Reshetenko et al.

    Study of low concentration CO poisoning of Pt anode in a proton exchange membrane fuel cell using spatial electrochemical impedance spectroscopy

    J. Power Sources

    (2014)
  • T. Reshetenko et al.

    Tolerance of non-platinum group metals cathodes proton exchange membrane fuel cells to air contaminants

    J. Power Sources

    (2016)
  • J. Stumper et al.

    In-situ methods for the determination of current distributions in PEM fuel cells

    Electrochim. Acta

    (1998)
  • G. Bender et al.

    Further refinements in the segmented cell approach o diagnosing performance in polymer electrolyte fuel cells

    J. Power Sources

    (2003)
  • T.V. Reshetenko et al.

    Systematic study of back pressure and anode stoichiometry effects on spatial PEMFC performance distribution

    Electrochim. Acta

    (2011)
  • T.V. Reshetenko et al.

    A segmented cell approach for studying the effects of serpentine flow field parameters on PEMFC current distribution

    Electrochim. Acta

    (2013)
  • O.E. Herrera et al.

    Anode and cathode overpotentials and temperature profiles in a PEMFC

    J. Power Sources

    (2012)
  • M.-L. Yang et al.

    Density functional study of the chemisorption of C1, C2 and C3 intermediates in propane dissociation on Pt (111)

    J. Mol. Catal. A

    (2010)
  • A.M. Gabelnick et al.

    Propylene deep oxidation on the Pt (111) surface: temperature programmed studies over extended coverage ranges

    Surf. Sci.

    (1999)
  • F. Bournel et al.

    Adsorption of some substituted ethylene molecules on Pt (111) at 95 K. Part I: NEXAFS, XPS and UPS studies

    Surf. Sci.

    (1996)
  • F. Bournel et al.

    Adsorption of some substituted ethylene molecules on Pt (111) at 95 K. Part II: a FT-RAIRS study

    Surf. Sci.

    (1996)
  • H. Li et al.

    Comparative electrochemical degradation of phthalic acid ester using boron-doped diamond and Pt anodes

    Chemosphere

    (2010)
  • N.-C. Shang et al.

    Oxidation of methyl methacrylate from semiconductor wastewater by O3 and O3/UV processes

    J. Hazard Mater.

    (2007)
  • D.-R. Ji et al.

    Treatment of methyl methacrylate from semiconductor wastewater by catalytic wet oxidation

    J. Taiwan Inst. Chem. Eng

    (2010)
  • P.T. Almazán-Sánchez et al.

    Wastewater treatment of methyl methacrylate (MMA) by Fenton's reagent and adsorption

    Catal. Today

    (2014)
  • Z. Qi et al.

    Performance of 2-propanol in direct-oxidation fuel cells

    J. Power Sources

    (2002)
  • D. Cao et al.

    A direct 2-propanol polymer electrolyte fuel cell

    J. Power Sources

    (2003)
  • T. Kobayashi et al.

    Direct alcohol fuel cell – relation between the cell performance and the adsorption of intermediates originating in the catalyst-fuel combinations

    J. Power Sources

    (2003)
  • E. Pastor et al.

    Electroreactivity of isopropanol on platinum in acids studied by DEMS and FTIRS

    J. Electroanal. Chem.

    (1995)
  • S.-G. Sun et al.

    In situ spectroscopic investigations of reaction mechanism of isopropanol oxidation on platinum single crystal electrodes

    Electrochim. Acta

    (1996)
  • S.-G. Sun et al.

    Kinetics of isopropanol oxidation on Pt (111), Pt (110), Pt (100), Pt (610) and Pt (211) single crystal electrodes – studies of in situ time-resolved FTIR spectroscopy

    Electrochim. Acta

    (1998)
  • B. Habibi et al.

    Electrooxidation of 2-propanol and 2-butanol on the Pt-Ni alloy nanoparticles in acidic media

    Electrochim. Acta

    (2013)
  • N. Burgos et al.

    Deep oxidation of VOC mixtures with platinum supported on Al2O3/Al monoliths

    Appl. Catal. B

    (2002)
  • J. Ge et al.

    PEMFC cathode catalyst contamination evaluation with a RRDE- propene and naphthalene

    Electrochim. Acta

    (2014)
  • J. Ge et al.

    PEMFC cathode catalyst contamination evaluation with a RRDE- methyl methacrylate

    Int. J. Hydrogen Energy

    (2014)
  • M. Boillot et al.

    Residence time distributions of gases in lab-scale polymer electrolyte membrane fuel cells (PEMFC)

    Chem. Eng. Sci.

    (2005)
  • D. Imamura et al.

    Effect of air contaminants on electrolyte degradation in PEMFC

    ECS Trans.

    (2009)
  • Y. Garsany et al.

    Impact of SO2 on the oxygen reduction reaction at Pt/Vulcan carbon electrocatalysts

    J. Electrochem. Soc.

    (2007)
  • Cited by (19)

    • Spatial performance of high- and low-Pt loaded proton exchange membrane fuel cells under cathode exposure to nitrogen dioxide

      2021, Journal of Power Sources
      Citation Excerpt :

      However, lowering the Pt content while maintaining the same performance and durability is a high-priority problem for the fuel cell industry [3–5]. In addition, the operation of PEMFCs using ambient air has revealed the serious negative impacts of common air impurities such as SO2, NO2 and volatile organic compounds on fuel cell performance and durability, causing premature and irreversible degradation [6–20]. NO2 is a common air contaminant that is constantly monitored by the US Environmental Protection Agency.

    • One-step microwave-assisted synthesis of carbon-supported ternary Pt-Sn-Rh alloy nanoparticles for fuel cells

      2020, Journal of the Taiwan Institute of Chemical Engineers
      Citation Excerpt :

      In recent years, the focus has been on developing multi-component (bimetallic or ternary) catalysts to modify the electronic structure of platinum, thus promoting better catalytic efficiency [23-25]. The combination of Pt and non-precious metals provides an efficient way to decrease the dosage of Pt and to further enhance the tolerance to poisoning [26,27]. Although many Pt-based bimetallic catalysts have been well characterized in the literature, they are still very limited for alcohol oxidation reaction performance [28,29].

    • Study of degradation and spatial performance of low Pt-loaded proton exchange membrane fuel cells under exposure to sulfur dioxide in an oxidant stream

      2020, Journal of Power Sources
      Citation Excerpt :

      However, ambient air typically contains a variety of inorganic and organic pollutants as well as particulates originating from natural and anthropogenic emission sources. All of these airborne contaminants compromise the performance of commercial high-Pt membrane electrode assemblies (MEAs), as shown in previous publications [7–21]. Among these impurities, SO2 is of special interest due to its high concentration in urban air (from 5 to 20 ppb to several ppm) [22–24] and its strong and irreversible effects on PEMFCs [7,8,25–40].

    View all citing articles on Scopus
    View full text