Rejection of submicron sized particles from swimming pool water by a monolithic SiC microfiltration membrane: Relevance of steric and electrostatic interactions

https://doi.org/10.1016/j.memsci.2015.10.033Get rights and content

Highlights

  • Surrogate challenge tests were carried out using a novel SiC MF membrane.

  • MS2 phages and microspheres were appropriate to surrogate relevant pathogenic viruses.

  • Physical sieving was predicted based on the pore size distribution of the membrane.

  • Organics and salts affect electrostatic properties and the rejection of surrogates.

  • Pore blockage increased the removal effectivity for large surrogates (~500 nm).

Abstract

The rejection of submicron sized particles from swimming pool water by a ceramic silicon carbide (SiC) microfiltration membrane in monolithic configuration was investigated and mechanisms elucidated.

Physicochemical properties showed that the surrogates used in challenge tests (i.e. MS2 bacteriophages and 50–500 nm fluorescent microspheres) are adequate surrogates for viruses commonly found in pool water.

The log-removal value (LRV) of the SiC membrane strongly depended on the size and electrostatic properties of the surrogates. Experiments with swimming pool water showed that organic matter and salts present in the pool water decreased the surface potential of the surrogates which in turn increased the LRV of the SiC membrane.

Long-term experiments revealed, that the removal effectivity of the SiC membrane, over the course of a filtration cycle (~150 min), increased for large surrogates (500 nm microspheres), while the removal effectivity remained unchanged for small surrogates (MS2 phages). This effect was explained by progressive and permanent blockage of large mesopores (>500 nm) in the active membrane layer by particles present in the pool water.

Section snippets

Introduction and objectives

Chlorine-based disinfection is widely used in swimming pool water treatment to ensure hygienic safety by inactivation of pathogenic microorganisms, namely viruses, bacteria and protozoa. However, the disinfection effectivity of chlorine is lowered as planktonic microorganisms attach to particles [1], [2], [3], [4], [5] which are introduced into pool water by the bathers [6]. As a result of the lowered disinfection effectivity, the potential of an outbreak in swimming pool facilities increases.

Preparation of stock suspensions

As typical concentrations of microorganisms found in swimming pool water are too low to provide proof of high log-removal values (<100 cfu mL−1 [45], [46]), suspensions of surrogates were used in this study. Surrogates are model particles of the size, surface charge and shape of interest. Two different types of surrogates, MS2 phages and spherical polystyrene fluorescent microspheres were used.

MS2 phages (ATCC 15597-B1) were purchased from the German Collection of Microorganisms and Cell Cultures

ζ-potential of the surrogates and the active membrane layer

Surface properties of relevant virus and bacteria are typically reported for solutions of monovalent cations in a concentration range of 0.01–0.03 M (Table 1). Thus, for the purpose of comparison with previous studies, ζ-potentials discussed in this section were determined in solutions of 0.01 M NaCl (Fig. 3) only.

At neutral conditions, all surrogates suspended in 0.01 M NaCl revealed a negative surface charge. The fluorescent microspheres comprised a significantly lower ζ-potential of −54.6 mV (200

Summary and conclusions

The present work reports the removal effectivity of a novel monolithic SiC MF membrane (carrier, primer and active membrane layer made of SiC) for submicron sized particles. Moreover, the impact of steric and electrostatic interactions between the used particles and the active membrane layer of the SiC membrane on the overall removal of the SiC membrane were identified.

MS2 phages and fluorescent microspheres were used for the rejection experiments. The MS2 phages comprised an isoelectric point

Acknowledgments

The authors wish to thank Dr. Sandro Wolf and Dr. Marina Totrova for their help in MS2 phage analysis and for making it possible to use the micro plate reader. The help of Dr.-Ing. André Lerch for his advice during the construction of the pilot plant and Dr. Ronald Neufert is greatly appreciated. Dipl.-Ing. Susanne Goldberg is thanked for SEM analysis of the SiC membrane.

References (86)

  • F.W. Pontius et al.

    Fluorescent microspheres as virion surrogates in low-pressure membrane studies

    J. Membr. Sci.

    (2009)
  • S.H. Choi et al.

    Use of fluorescent silica particles for checking the integrity of microfiltration membranes

    J. Membr. Sci.

    (2011)
  • F.W. Pontius et al.

    Virus passage through compromised low-pressure membranes: A particle tracking model

    J. Membr. Sci.

    (2011)
  • C.M. Schaldach et al.

    The influence of ionic strength on the interaction of viruses with charged surfaces under environmental conditions

    J. Colloid Interface Sci.

    (2006)
  • M. Grce et al.

    Antiviral properties of clinoptilolite

    Microporous Mesoporous Mater.

    (2005)
  • T. Schinner et al.

    Transport of selected bacterial pathogens in agricultural soil and quartz sand

    Water Res.

    (2010)
  • E.M. van Voorthuizen et al.

    Role of hydrophobic and electrostatic interactions for initial enteric virus retention by MF membranes

    J. Membr. Sci.

    (2001)
  • M.G.A. Keuten et al.

    Definition and quantification of initial anthropogenic pollutant release in swimming pools

    Water Res.

    (2012)
  • M. Guida et al.

    Microbiological quality of the water of recreational and rehabilitation pools: a 2-year survey in Naples, Italy

    Public Health

    (2009)
  • J. Ibarluzea et al.

    Determinants of the microbiological water quality of indoor swimming-pools in relation to disinfection

    Water Res.

    (1998)
  • E. Joyce et al.

    The development and evaluation of ultrasound for the treatment of bacterial suspensions. A study of frequency, power and sonication time on cultured Bacillus species

    Ultrason. Sonochem.

    (2003)
  • H. Guo et al.

    Low-pressure membrane integrity tests for drinking water treatment: A review

    Water Res.

    (2010)
  • A. Julbe et al.

    New approaches in the design of ceramic and hybrid membranes

    J. Membr. Sci.

    (2008)
  • A. Sze et al.

    Zeta-potential measurement using the Smoluchowski equation and the slope of the current-time relationship in electroosmotic flow

    J. Colloid Interface Sci.

    (2003)
  • Y. Wyart et al.

    Membrane characterization by microscopic methods: Multiscale structure

    J. Membr. Sci.

    (2008)
  • I. Masselin et al.

    Membrane characterization using microscopic image analysis

    J. Membr. Sci.

    (2001)
  • V. Singh et al.

    Development of membrane based technology for the separation of coal from organic solvent

    Desalination

    (2012)
  • C. Suh et al.

    Application of genetic programming to develop the model for estimating membrane damage in the membrane integrity test using fluorescent nanoparticle

    Desalination

    (2011)
  • V. Gitis et al.

    Fluorescent dye labeled bacteriophages-a new tracer for the investigation of viral transport in porous media: 1. Introduction and characterization

    Water Res.

    (2002)
  • S. Salgin et al.

    Zeta Potentials and Isoelectric Points of Biomolecules: The Effects of Ion Types and Ionic Strengths

    Int. J. Electrochem. Sci.

    (2012)
  • Y. Zhang et al.

    Impact of natural organic matter and divalent cations on the stability of aqueous nanoparticles

    Water Res.

    (2009)
  • E.L. Sharp et al.

    Seasonal variations in natural organic matter and its impact on coagulation in water treatment

    Sci. Total. Environ.

    (2006)
  • E. Tombacz et al.

    Adsorption of organic acids on magnetite nanoparticles, pH-dependent colloidal stability and salt tolerance

    Colloids Surf. Physicochem. Eng. Asp.

    (2013)
  • S.A. Huber et al.

    Characterisation of aquatic humic and non-humic matter with size-exclusion chromatography-organic carbon detection-organic nitrogen detection (LC-OCD-OND)

    Water Res.

    (2011)
  • M. Pham et al.

    Deposition kinetics of bacteriophage MS2 to natural organic matter: Role of divalent cations

    J. Colloid Interface Sci.

    (2009)
  • S. Panglisch et al.

    Monitoring the integrity of capillary membranes by particle counters

    Desalination

    (1998)
  • J. Langlet et al.

    Efficiency of MS2 phage and Q beta phage removal by membrane filtration in water treatment: Applicability of real-time RT-PCR method

    J. Membr. Sci.

    (2009)
  • N. Shirasaki et al.

    Estimation of norovirus removal performance in a coagulation-rapid sand filtration process by using recombinant norovirus VLPs

    Water Res.

    (2010)
  • B. Örmerci et al.

    Comparison of UV and chlorine inactivation of particle and non-particle associated coliform

    Water Sci. Technol. Water Supply

    (2002)
  • D. Berman et al.

    Inactivation of Particle-Associated Coliforms by Chlorine and Monochloramine

    Appl. Environ. Microbiol.

    (1988)
  • V. Gauthier et al.

    Chlorine inactivation of Sphingomonas cells attached to goethite particles in drinking water

    Appl. Environ. Microbiol.

    (1999)
  • DIN 19643-19645

    Treatment of water of swimming-pools and baths. Part 5: Combination of process: flocculation – filtration – adsorption at granular activated carbon – chlorination (in German). Normenausschuss Wasserwesen (NAW) im DIN Deutsche Institut für Normung

    (2000)
  • J.E. Amburgey

    Removal of Cryptosporidium-Sized Polystyrene Microspheres from Swimming Pool Water with a Sand Filter with and without Added Perlite Filter Media

    J. Environ. Eng.

    (2011)
  • Cited by (22)

    • Filtration for removal of microparticles in swimming pool water

      2024, Separation and Purification Technology
    • Characterization and chlorine reactivity of particulate matter released by bathers in indoor swimming pools

      2023, Chemosphere
      Citation Excerpt :

      Combining sand filtration with granular activated carbon filtration has been proven to be the most effective treatment for reducing DBPs and their precursors; however, conventional water treatment techniques combining (or not combining) coagulation and sand filtration remain the most widely utilized methods (Lee et Blatchley, 2022). Nonetheless, during the filtration step, dissolved and undissolved compounds are retained on the filter media (Amburgey et al., 2012), where they are exposed to chlorinated water and can form new or additional DBPs, until the backwashing process is initiated (Skibinski et al., 2016). The reactivity between chlorine and DOM brought by bathers has been the subject of numerous studies, and a solution simulating DOM brought by bathers has been formulated (body fluid analogs (BFA)) (Borgmann-Strahsen, 2003; Goeres et al., 2004; Judd and Black., 2000; Judd and Bullock., 2003).

    • Effect of concentration on virus removal for ultrafiltration membrane in drinking water production

      2021, Journal of Membrane Science
      Citation Excerpt :

      First, “low quality” waters typically with high turbidity and organic matter can cause membrane fouling, with pore clogging, pore size diminution and formation of a layer cake, which can enhance the viral retention [64]. Then, electrostatic and hydrophobic interactions can be influenced by various water characteristics as pH, ionic strength, type of ions in solution or turbidity [8,25,65,66]. Dishari et al. observed optimal conditions for viral removal with low pH and low ionic strength [65].

    • Highly permeable silicon carbide-alumina ultrafiltration membranes for oil-in-water filtration produced with low-pressure chemical vapor deposition

      2020, Separation and Purification Technology
      Citation Excerpt :

      Therefore, it is assumed that the surface properties of the SiC-deposited layer are the most important in avoiding fouling. Previous studies also showed that SiC membranes have a low fouling tendency as compared to other ceramic and polymeric membranes, which is closely related to super hydrophilicity [8] and the low iso-electric point (pH 2.8) of SiC [9]. The pristine alumina membrane has a relatively high iso-electric point which is about 9 [40].

    View all citing articles on Scopus
    View full text